Connecting a MELSEC PLC over SLMP
A MELSEC CPU (Q, L, iQ-R or iQ-F) answers SLMP on its Ethernet module. The simulator uses this to write
the scene's sensors into the CPU's devices and read its outputs back, while your program runs on the CPU.
A part's PLC tag is the CPU's own device address: M10, Y10, D100.
SLMP has no authentication and no encryption. Use it on this machine or a test bench, not a plant network.
You need
- The desktop app, for Windows or Linux. A browser tab cannot open a network connection.
- A MELSEC CPU with an Ethernet module or built-in Ethernet port, and its engineering software (GX Works3 for an iQ-R or iQ-F).
- A network path from this computer to the CPU, on the port its SLMP connection answers on. The usual port is 5000. A simulated CPU works only if its simulator opens an SLMP connection this computer can reach.